-40%

D4MC-5020 Enclosed Limit Switch SPDT Roller Panel Mount Plunger B30

$ 4.19

Availability: 1107 in stock
  • Mounting Style: Panel
  • Condition: New
  • Refund will be given as: Money Back
  • Brand: endlessparts
  • MPN: D4MC-5020
  • All returns accepted: Returns Accepted
  • Model: D4MC-5020
  • Restocking Fee: No
  • Return shipping will be paid by: Seller
  • Item must be returned within: 30 Days

    Description

    Package Included
    D4MC-5020 Enclosed Limit Switch SPDT Roller, Panel Mount Plunger
    -------------------------------------------
    Operating mechanism
    Snap action
    Actuator
    Panel mount roller plunger
    Frequency
    50/60 Hz
    Switching mechanism
    Self-reset mechanism
    Contact configuration
    Single-Pole, Double-Throw type
    Contact form
    SPDT
    Load
    General load
    Ratings (AC): Non-Inductive load
    Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO)
    Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2.5 A (NC) 1.25 A (NO)
    Rated voltage: 480 VAC, Resistive load: 3 A (NC) 3 A (NO), Lamp load: 1.5 A (NC) 0.75 A (NO)
    Ratings (AC): Inductive load
    Rated voltage: 125 VAC, Inductive load: 10A (NC) 10A (NO), Motor load: 5A (NC) 2.5A (NO)
    Rated voltage: 250 VAC, Inductive load: 10A (NC) 10A (NO), Motor load: 3A (NC) 1.5A (NO)
    Rated voltage: 480 VAC, Inductive load: 2.5A (NC) 2.5A (NO), Motor load: 1.5A (NC) 0.75A (NO)
    Ratings (DC): Non-Inductive load
    Rated voltage: 8 VDC, Resistive load: A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO)
    Rated voltage: 14 VDC, Resistive load: A (NC) 10 A (NO), Lamp load: 3 A (NC) 1.5 A (NO)
    Rated voltage: 30 VDC, Resistive load: A (NC) 6 A (NO), Lamp load: 3 A (NC) 1.5 A (NO)
    Rated voltage: 125 VDC, Resistive load: A (NC) 0.5 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO)
    Rated voltage: 250 VDC, Resistive load: A (NC) 0.25 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO)
    Ratings (DC): Inductive load
    Rated voltage: 8 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load : 5 A (NC) 2.5 A (NO)
    Rated voltage: 14 VDC, Inductive load: 6 A (NC) 6 A (NO), Motor load : 5 A (NC) 2.5 A (NO)
    Rated voltage: 30 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load : 5 A (NC) 2.5 A (NO)
    Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load : 0.05 A (NC) 0.05 A (NO)
    Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load : 0.03 A (NC) 0.03 A (NO)
    Explanation
    The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current.
    Inrush current
    NC: 30 A
    NO: 15 A
    Ambient temperature
    Operating: -10 to 80 ℃
    Ambient humidity
    Operating: 35 to 95 % RH
    Characteristics
    Permissible operating speed
    0.05 mm/s to 0.5 m/s
    Permissible operating speed (Mechanically)
    120 operations / 1 minute Max.
    Permissible operating speed (Electrically)
    20 operations / 1 minute Max.
    Contact resistance
    15 mOhm Max. (Initial value)
    (Measuring method is contact resistance meter.)
    Insulation resistance
    Between each terminal of the same polarities: 100 MOhm Min.
    Between live-metallic part and ground: 100 MOhm Min.
    Between each terminal and non-live-metallic part: 100 MOhm Min.
    (at 500 VDC Megger)
    Dielectric strength
    Between each terminal of the same polarities: 1,000 VAC
    Between live-metallic part and ground: 2,000 VAC
    Betweeneachterminalandnon-live-metallicpart: 2,000 VAC
    Durability (Mechanically)
    10,000,000 operations Min. (No load)
    (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
    Durability (Electrically)
    500,000 operations Min. * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC)
    (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
    Vibration resistance (Malfunction)
    Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
    Shock resistance (Destruction)
    1,000 m/s2
    Shock resistance (Malfunction)
    Contact opening is 1 ms Max. at the free position and the total travel position at 100 m/s2.
    Degree of protection
    IEC60529 (JEM): IP67
    Applicable standard (UL)
    Standard No.: UL508
    File number: E76675
    Applicable standard (CSA)
    Standard No.: C22.2 NO.14
    File number: LR45746
    Applicable standard (CCC (CQC) )
    Standard No.: GB14048.5
    File number: 2003010303077627
    Applicable standard (EC Directive (Low Voltage Directive) )
    2006/95/EC
    Mounting specification
    Panel mounting, Side mounting
    Operating characteristics
    Operating Force (OF)
    Standard value 5.88 N Max.
    Release Force (RF)
    Standard value 0.98 N Min.
    Pre-Travel (PT)
    Standard value 1.6 mm Max.
    Over-Travel (OT)
    Standard value 5 mm Min.
    Movement Differential (MD)
    Standard value 0.2 mm Max.
    Operating Position (OP)
    Standard value 33.4 +/- 1.2 mm